TECHNICAL WHITE PAPER / 21
Technical Note: Using VMware vCenter Chargeback
Manager with VMware vCloud Director
Calculating Resource Costs
Base-rate calculation includes: time interval* rate cost* used units* rate factor.

and no rate factor: 2 hours* $0.02 USD GHz/hour* 10GHz* 1.0 = $0.4 USD.

following result: 2 hours* $0.05 USD GB/hour* 20GB* 1.0 = $2 USD.
If the billing policy is set to charge based on usage instead of allocation, the used units is the usage value for the
resource that is obtained from vCenter Server.
At the virtual machine level, the billing policy dictates whether costs are applied for the entire report duration or
for only the duration when a virtual machine is powered on.
Calculating Fixed Costs
time interval* fixed cost/duration of the resource.

in the following: 2 hours* $125 USD/168 hours in a week = $1.49 USD.
Calculating VM Instance Costs
The second virtual machine is powered o during the middle of the reporting interval. The time interval for this

and are applied only for the duration when a virtual machine is powered on. The change in virtual machine size
will trigger a separate line item in the report, reflecting the configuration change and the new fixed cost applied.
The two totals are added together for the final cost.
User Management
vCenter Chargeback Manager does not extract, consume or sync with vCloud Director user logins, roles or
permissions. After initial installation of vCenter Chargeback Manager, an administrator user is created in it, and
all the vCloud Director objects belong to this user. Only the administrator/supervisor user can grant permissions.
There are no per-organization users, and no vCloud Director user information is passed on to vCenter
Chargeback Manager.

their organizations.
Creating users




Assigning roles to users
•Assigning a role on vCenter Chargeback Manager, other than the supervisor user role, defines only the actions
that the user can perform in the application. This does not implicitly give access to the resources created in the
application. To access a resource, the user either must have created it or explicitly be assigned a role for it.