EMC Infrastructure for Virtual Desktops Enabled by EMC VNX Series,
VMware vSphere 4.1, VMware View 4.5, and VMware View Composer 2.5 Proven Solution Guide
42
FAST Cache
IOPS
The following graph shows the IOPS serviced from FAST Cache during the boot
storm test.
At peak load, FAST Cache serviced around 9,250 IOPS from the linked clone data
stores, which is the equivalent of 47 FC disks servicing 200 IOPS each.
ESX CPU load
The following graph shows the CPU load from the ESX servers in the View cluster.
All servers had similar results. Therefore, a single server is reported.
The ESX server briefly achieved a CPU utilization of approximately 55 percent
during peak load in this test.