Strany 1 - User Manual

P007997-01A Rev. B Emulex Connects™ Servers, Storage and PeopleOneCommand™ Manager ApplicationVersion 6.1User Manual

Strany 2

OneCommand™ Manager Application P007997-01A Rev. B List of Figures10List of FiguresFigure 2-1 OCManager Enterprise Installation Options Window...

Strany 3 - Table of Contents

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1005. Click Yes. The Change World Wide Name Configuration dial

Strany 4 - Table of Contents

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE101Note: If the adapter or firmware does not support Volatile W

Strany 5

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1022. From the discovery-tree, select the adapter port on which

Strany 6

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE103where x is a hexadecimal valueNote: Ensure that a manually e

Strany 7

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1042. From the discovery-tree, select the virtual port you want

Strany 8

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE105Figure 8-23 Delete Virtual Port WarningNote: The link on th

Strany 9

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE106To change the name of an adapter:1. From the discovery-tree,

Strany 10 - List of Figures

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE107The following warning appears:Figure 8-24 Reset Warning3. C

Strany 11 - List of Figures

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE108Note: This section only applies to FC and FCoE adapters. It

Strany 12

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE109 Figure 8-25 Host Driver Parameters TabHost Driver Paramete

Strany 13 - List of Tables

OneCommand™ Manager Application P007997-01A Rev. B List of Figures11Figure 8-18 Maintenance Tab ...

Strany 14 - 1. Introduction

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE110 Apply – Click to apply any driver parameter changes. If yo

Strany 15 - Compatibility

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE111 Figure 8-26 Driver Parameters Tab – Adapter Selected4. In

Strany 16 - Abbreviations

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE112Restoring All Parameters to Their Earlier ValuesIf you chang

Strany 17

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE113Setting Driver Parameters for All Adapters in a HostTo chang

Strany 18 - In Windows

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1146. To make a change temporary (the parameter to revert to it

Strany 19

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE115Creating a Batch Mode Driver Parameters FileYou can apply dr

Strany 20 - In Linux

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1163. The Driver Parameter File Selection dialog box appears. S

Strany 21 -  For RHEL 5 and RHEL 6 type:

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE117Checkboxes next to the host and adapter entries are used to

Strany 22 - In Solaris

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE118Configuring FCoE Initialization Protocol (FIP)The FIP tab en

Strany 23

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE119the DCB tab). If CIN (Non-FIP) was the current DCBX mode, “A

Strany 24 - In VMware ESX Server

OneCommand™ Manager Application P007997-01A Rev. B List of Figures12Figure 8-58 Install Feature Licenses Dialog Box...

Strany 25 - --maintenancemode update

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1202. Select the DCB tab. Figure 8-31 DCB Tab (FCoE Adapter Po

Strany 26 - Web Launch Interface

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE121PFC Properties Area State – Enabled means that flow control

Strany 27 - Installation

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE1223. Click Configure DCB. The Configure DCB dialog box appears

Strany 28 -  Linux:

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE123LLDP Settings Area Transmit Enabled – LLDP Transmit can be

Strany 29 - Web Launch Interface Only

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI124Configure DCB Dialog Box Buttons Defaults – Click to return p

Strany 30 - /opt/ELXocm/wsuninstall

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1253. Select the iSCSI Port Information tab. Figure 8-33 iSCSI P

Strany 31 - Manager Application

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI126TCP/IP Configuration Area  DHCP Enabled – The DHCP authentica

Strany 32 - Launch Interface

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1273. Select the VPD tab. Figure 8-34 OneConnect VPD TabVPD Tab

Strany 33

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI128To view iSCSI port statistics:1. Select Host view.2. Select an

Strany 34 - Element Definitions

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI129 Last Session Remote Node Name – The iSCSI name of the remote

Strany 35 - Toolbar Buttons

OneCommand™ Manager Application P007997-01A Rev. B List of Tables13List of TablesTable 5-1 Namespaces Used for Providers...

Strany 36

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI130Viewing iSCSI Target InformationWhen you select a target assoc

Strany 37 - Discovery-Tree

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI131Target Portal Information Area IP Address – The IP address th

Strany 38 - Property Tabs

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1322. From the discovery-tree, select the iSCSI LUN whose informa

Strany 39 - Status Bar

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI133Viewing iSCSI PCI RegistersThe iSCSI PCI Registers tab display

Strany 40 - Management Host

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1342. Select the DCB tab. Figure 8-39 DCB Tab for iSCSI Adapter

Strany 41 - 2. Run the following script:

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI135PFC Properties AreaNote: PFC is not supported on all the iSCSI

Strany 42 - 5. Configuring Discovery

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1363. Click Configure DCB. The Configure DCB dialog box appears.4

Strany 43 - Hosts File

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI137LLDP Settings Area Transmit Enabled – LLDP Transmit can be en

Strany 44

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI138 Bandwidth % – The configured value of bandwidth for the diff

Strany 45 - Adding a Single Host

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI139Figure 8-41 Modify TCP/IP Configuration Dialog BoxTo modify T

Strany 46 - Adding a Range of Hosts

OneCommand™ Manager Application P007997-01A Rev. B1. Introduction141. IntroductionThe Emulex® OneCommandTM Manager application is a comprehensive mana

Strany 47

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI140Advanced TCP/IP ConfigurationThe Advanced TCP/IP Configuration

Strany 48 - Removing Hosts

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI141Configuring iSCSI Port Initiator Login OptionsThe iSCSI Initia

Strany 49

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI142Initiator Login Options Area ImmediateData – Defines whether

Strany 50

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsiSCSI1433. Click Apply Changes. Note: Any changes to the iSCSI initiat

Strany 51

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC144 DataSequenceInOrder – The order between sequences. HeaderDige

Strany 52 - Removing a Target Portal

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1453. Select the Port Information tab. Figure 8-45 NIC Port Inform

Strany 53 - Figure 5-7 iSCSI SNS Tab

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC146 Current MTU – The current transmission unit for iSCSI traffic.

Strany 54 - Logging into Targets

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1473. Select the VPD tab. Figure 8-46 OneConnect VPD TabVPD Table

Strany 55 - Removing Targets

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC148Configuring DCB Parameters for NIC-Only Adapter PortsThe DCB tab

Strany 56 - Viewing Target Sessions

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC149PFC Properties AreaNote: PFC is not supported on all the iSCSI a

Strany 57

OneCommand™ Manager Application P007997-01A Rev. B1. IntroductionCompatibility15 Enable or disable adapter boot (x86 BootBIOS, FCode, EFIBoot, or PXE

Strany 58 - Session Statistics Area

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1503. Click Configure DCB. The Configure DCB dialog box appears.4.

Strany 59 - Connection Information Area

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC151LLDP Settings Area Transmit Enabled – LLDP Transmit can be enab

Strany 60

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC152Configure DCB Dialog Box Buttons Configuration Rules – Click to

Strany 61 - 7. Managing Hosts

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC1534. Check or uncheck Enable SR-IOV. Figure 8-49 Port Information

Strany 62 - Function Summary Area

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC154The NIC for the discovered guest operating system matches one of

Strany 63

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsNIC155 Operating System – The operating system and version installed

Strany 64 - Grouping Hosts

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters156Viewing NIC PCI RegistersThe NIC PCI Registers t

Strany 65 - Managing Host Groups

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1572. Select a OneConnect adapter in the discovery-

Strany 66 - Deleting a Host Group

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters158adapter's temperature and one of the follow

Strany 67 - Restoring all Host Groups

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters159To view general ASIC information:1. Select Host

Strany 68 - Searching for Hosts

OneCommand™ Manager Application P007997-01A Rev. B1. IntroductionKnown Issues16OneCommand Manager for VMware vCenter software plug-in. For more detail

Strany 69 - Using CIM

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters160 Exceeded operational range – Critical: The ada

Strany 70

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1612. Select a OneConnect multi-ASIC adapter in the

Strany 71 - Viewing FC Port Information

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters162Using the Adapter Information tab, you can view

Strany 72

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters163 Figure 8-57 Licensed Features WindowInstalli

Strany 73 - Viewing FCoE Port Information

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1643. Following the instructions you received with

Strany 74

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters165 Figure 8-59 OneConnect Adapter Information T

Strany 75

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters166Note: iSCSI and NIC-Only adapters do not appear

Strany 76 - Figure 8-4 Statistics Tab

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters167 UEFI FCODE – The single flash image containing

Strany 77

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters168Enabling and Disabling OneConnect Physical Ports

Strany 78

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters169Viewing PHY Data (OneConnect 10GBASE-T series Ad

Strany 79

OneCommand™ Manager Application P007997-01A Rev. B1. IntroductionAbbreviations17LPFC LightPulse Fibre ChannelLUN logical unit numberMAC media access c

Strany 80

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters170Error Rates Area Low Density Parity Check (LDPC

Strany 81

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters1713. Select the Transceiver Data tab.Figure 8-64

Strany 82

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsOneConnect Adapters172Diagnostic Data Area Temperature – The internal

Strany 83 - Firmware Area

OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)Linux Considerations1739. Using

Strany 84 - WWN Management Area

OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)Enabling Authentication174lpfc_

Strany 85

OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)DHCHAP Tab175DHCHAP TabThe DHCH

Strany 86

OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)DHCHAP Tab176 Disabled – The a

Strany 87 - Mapping Information Area

OneCommand™ Manager Application P007997-01A Rev. B9. Using FC-SP DHCHAP Authentication (Windows, Linux 8.2 and Solaris)DHCHAP Tab177Note: To successfu

Strany 88 - /usr/sbin/lpfc/lun_scan all

OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for a Single Adapter17810. Updating Adapter FirmwareT

Strany 89 - LUN Masking Area

OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for a Single Adapter1793. Select the Maintenance or F

Strany 90 - Display Mode Radio Buttons

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 91

OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for Multiple Adapters180Updating Firmware for Multipl

Strany 92 - Target Mapping Buttons

OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for Multiple Adapters181 Figure 10-2 Batch Firmwar

Strany 93 - Figure 8-14 LUN Masking Tab

OneCommand™ Manager Application P007997-01A Rev. B10. Updating Adapter FirmwareUpdating Firmware for Multiple Adapters182Figure 10-3 Batch Firmware D

Strany 94

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Types18311. Configuring Boot from an FC SANYou can use the O

Strany 95 - Adding a Persistent Binding

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters184Boot Device ParametersThe boot LUN for a

Strany 96

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters185Adapter Boot checkbox and Configure Boot

Strany 97

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters186Note: Topology and link speed are not av

Strany 98

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANBoot Device Parameters187Figure 11-2 Select Boot Device Window (

Strany 99 - Figure 8-18 Maintenance Tab

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)188Configuring Advan

Strany 100

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)189x86 Boot Advanced

Strany 101 - Creating Virtual Ports

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 102 - 3x:xx:xx:xx:xx:xx:xx:xx

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)190interval scans th

Strany 103 - Deleting Virtual Ports

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)191 None EFIBootFC

Strany 104 - Figure 8-22 Virtual Port Tab

OneCommand™ Manager Application P007997-01A Rev. B11. Configuring Boot from an FC SANConfiguring Advanced Settings (Boot from SAN)192OpenBoot Advanced

Strany 105

OneCommand™ Manager Application P007997-01A Rev. B12. Exporting SAN InformationCreating a SAN Report19312. Exporting SAN InformationCreating a SAN Rep

Strany 106

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics19413. DiagnosticsDiagnostic tests can only be performed

Strany 107 - Figure 8-24 Reset Warning

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics195Viewing Flash Contents, PCI Registers, and Wakeup Inf

Strany 108 - Activation Requirements

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics196Viewing Overlay DetailsIf you double-click on a flash

Strany 109

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics1972. Select the Diagnostics tab and click Quick Test. A

Strany 110 - Setting Driver Parameters

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics198Creating Diagnostic DumpsThe diagnostic dump capabili

Strany 111

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics1994. Click OK. Dump files are created. Where these file

Strany 112 - Parameter Value

OneCommand™ Manager Application P007997-01A Rev. B 2Copyright © 2003-2012 Emulex. All rights reserved worldwide. No part of this document may be repro

Strany 113

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 114

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics200To run advanced diagnostics tests, click Advanced Dia

Strany 115

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics201Loopback Test CombinationsRun the following loopback

Strany 116

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics2022. Select the Diagnostics tab and click Advanced Diag

Strany 117

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsLightPulse FC HBA Diagnostics203To run end-to-end echo tests:1. From the discovery-tr

Strany 118 - DCB Settings Area

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics204two-line header that contains the identifier of the adapter

Strany 119 - CIN Settings Area

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics205 Control adapter beaconing All functions are supported loca

Strany 120 - DCB Tab Field Definitions

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics206 MAC Loopback – MAC loopback connects the transmit output o

Strany 121

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics2073. Click Start. The following warning appears:Figure 13-13

Strany 122

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics208To enable or disable beaconing:1. From the discovery-tree, s

Strany 123

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics209Creating Diagnostic Dumps The diagnostic dump capabilit

Strany 124

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 125

OneCommand™ Manager Application P007997-01A Rev. B13. DiagnosticsOneConnect Diagnostics210 Linux – /usr/sbin/ocmanager/Dump VMware – a dump director

Strany 126 - Viewing iSCSI VPD Information

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingGeneral Situations21114. TroubleshootingThere are several circumstances in which

Strany 127 - Viewing iSCSI Statistics

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingGeneral Situations212In the OneCommand Manager application discovery-tree, multip

Strany 128

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingGeneral Situations213 Unwanted remote servers appear in the OneCommand Manage

Strany 129

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations214Emulex Dr

Strany 130

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations215Under cer

Strany 131 - Viewing iSCSI LUN Information

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations216Driver un

Strany 132

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations217Cannot se

Strany 133 - Viewing iSCSI PCI Registers

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Linux and OneCommand Manager Application Situations218 Unwanted

Strany 134

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingEmulex Driver for Solaris and OneCommand Manager Application Situations219Emulex

Strany 135

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 136 - DCBX Settings Area

OneCommand™ Manager Application P007997-01A Rev. B14. TroubleshootingVPorts and OneCommand Manager Application Situations220Port not ready. The contro

Strany 137 - ETS Priority Groups Area

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 138

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 139

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 140 - Advanced TCP/IP Configuration

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 141

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsInstalling the OneCommand Ma

Strany 142 - Authentication Area

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsUninstalling the OneCommand

Strany 143

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsUninstalling the OneCommand

Strany 144 - Viewing NIC Port Information

OneCommand™ Manager Application P007997-01A Rev. B Table of Contents3Table of ContentsList of Figures ...

Strany 145

OneCommand™ Manager Application P007997-01A Rev. B2. Installing and Uninstalling OneCommand Manager Application ComponentsUninstalling the OneCommand

Strany 146 - Viewing NIC VPD Information

OneCommand™ Manager Application P007997-01A Rev. B3. Starting and Stopping the OneCommand Manager ApplicationIn Windows313. Starting and Stopping the

Strany 147 - VPD Table Definitions

OneCommand™ Manager Application P007997-01A Rev. B3. Starting and Stopping the OneCommand Manager ApplicationIn VMware ESX Server32In VMware ESX Serve

Strany 148

OneCommand™ Manager Application P007997-01A Rev. B3. Starting and Stopping the OneCommand Manager ApplicationStarting the OneCommand Manager Applicati

Strany 149

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit

Strany 150

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit

Strany 151

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit

Strany 152

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit

Strany 153 - Base Host Operating System

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationThe OneCommand Manager Application Window Element Definit

Strany 154 - Guest Host Information Area

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationChanging Management and Read-Only Mode39Status BarThe sta

Strany 155 - Operating System

OneCommand™ Manager Application P007997-01A Rev. B Table of Contents4Expanding or Collapsing the Discovery-Tree View ...

Strany 156 - OneConnect Adapters

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationChanging Management and Read-Only Mode40 Read-only opera

Strany 157

OneCommand™ Manager Application P007997-01A Rev. B4. Using the OneCommand Manager ApplicationChanging Management and Read-Only Mode412. Choose the man

Strany 158 - Viewing ASIC Information

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryAutomatic FC Discovery425. Configuring DiscoveryAutomatic FC DiscoveryAdapte

Strany 159

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol43Discovery Using the TCP/IP Acces

Strany 160 - License Features Area

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol44 Adding a single host from the

Strany 161

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol45 Blank lines are ignored.3. Sav

Strany 162 - Showing Licenses

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol46 If you want to add the new hos

Strany 163 - Installing Licenses

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryDiscovery Using the TCP/IP Access Protocol47Figure 5-4 Add Range of TCP/IP

Strany 164

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring Discovery and CIM Credentials48Also, a host can have more than o

Strany 165

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring Discovery and CIM Credentials49host, the adapters of all these h

Strany 166 - Boot Code Versions Area

OneCommand™ Manager Application P007997-01A Rev. B Table of Contents5Adding a Host to a Host Group...

Strany 167

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring Discovery and CIM Credentials50Note: If the Emulex CIM Provider

Strany 168

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery51Configuring iSCSI Target DiscoveryThe iS

Strany 169 - PHY Data Field Definitions

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery52Target Discovery Buttons Add Portal – C

Strany 170 - Counters Area

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery53Configuring iSNS for iSCSI Target Discov

Strany 171 - Module Attributes Area

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery54To discover servers using DHCP, click Di

Strany 172 - Diagnostic Data Area

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery552. Click Target Login. The Target Login

Strany 173 - Enabling Authentication

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery56Viewing Target SessionsThe Target Sessio

Strany 174

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery57Note: If all sessions are logged out, th

Strany 175 - DHCHAP Tab

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery58 iSCSI Boot – Check this box to enable

Strany 176

OneCommand™ Manager Application P007997-01A Rev. B5. Configuring DiscoveryConfiguring iSCSI Target Discovery59 Connection Timeouts – The count of con

Strany 177 - Changing Your Password

OneCommand™ Manager Application P007997-01A Rev. B Table of Contents6Masking and Unmasking LUNs (Windows)...

Strany 178 - 10. Updating Adapter Firmware

OneCommand™ Manager Application P007997-01A Rev. B6. Viewing Discovery InformationDiscovery Information Field Definitions606. Viewing Discovery Inform

Strany 179

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsDiscovery Information Field Definitions617. Managing HostsThere are two tabs that s

Strany 180

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsHost Information Field Definitions62Host Information Field Definitions Operating S

Strany 181

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsViewing Host Grouping Information63Viewing Host Grouping InformationThe Host Group

Strany 182

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts64Grouping HostsThe OneCommand Manager application enables you to ass

Strany 183 - Boot Types

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts65Managing Host GroupsUse the Host Group Management dialog box to cre

Strany 184 - Boot Device Parameters

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts66 Remove Host – Removes selected hosts from the currently selected

Strany 185

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsGrouping Hosts673. Click Yes to delete the selected host group.Adding a Host to a H

Strany 186

OneCommand™ Manager Application P007997-01A Rev. B7. Managing HostsSearching for Hosts68the OneCommand installation directory to the equivalent locati

Strany 187

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsUsing CIM698. Managing Adapters and PortsThis section describes the va

Strany 188

OneCommand™ Manager Application P007997-01A Rev. B Table of Contents7Viewing iSCSI PCI Registers...

Strany 189

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE702. Select an FC adapter in the discovery-tree. Figure 8-1 FC

Strany 190

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE71 Exceeds operational range – Adapter stopped: The temperatur

Strany 191 -  200 ms

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE72FC Port Information Field DefinitionsPort Attributes Area Fie

Strany 192

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE73Loop Map Table Definitions The loop map shows the different

Strany 193 - 12. Exporting SAN Information

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE743. Select the Port Information tab. Figure 8-3 FCoE Port I

Strany 194 - 13. Diagnostics

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE75 Firmware Version – The version of Emulex firmware currently

Strany 195 - Viewing Flash Contents

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE763. Click the Statistics tab. Figure 8-4 Statistics TabPort S

Strany 196 - Running a Quick Test

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE77 Invalid Tx Words – The total number of invalid words transm

Strany 197 - Using Beaconing

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE78 Total SCSI I/O Count – The number of SCSI I/O requests rece

Strany 198 - Creating Diagnostic Dumps

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE79Virtual Port Information Field Definitions Number of Hosts –

Strany 199 - LightPulse FC HBA Diagnostics

OneCommand™ Manager Application P007997-01A Rev. B Table of Contents8PHY Data Field Definitions ...

Strany 200 - Running Loopback Tests

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE80Viewing FC Transceiver InformationWhen you select an FC port

Strany 201 - Loopback Test Combinations

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE81 Connector – The external optical or electrical cable connec

Strany 202

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE82VPD Table Definitions Product Name – Product information abo

Strany 203 - Saving the Log File

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE833. Select the Maintenance tab. Figure 8-9 FC Maintenance Tab

Strany 204 - OneConnect Diagnostics

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE84 “Not Present” if boot code is not loaded. If boot code is n

Strany 205

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE85Viewing FCoE Maintenance InformationUse the Maintenance to vi

Strany 206 - Test Status

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE86 ULP FW Name – The firmware version running on the (Upper La

Strany 207

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE872. In the discovery-tree, select the FC/FCoE target whose inf

Strany 208

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE88 On Linux systems, to make LUNs that are newly added to a st

Strany 209

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE89Mapping Information Area FCP LUN – The FC identifier used by

Strany 210

OneCommand™ Manager Application P007997-01A Rev. B Table of Contents9Running a Quick Test...

Strany 211 - 14. Troubleshooting

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE903. Select the Target Mapping tab.Figure 8-13 Target Mapping

Strany 212 - Situation Resolution

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE91Target Mapping Buttons Refresh – Click to refresh the Target

Strany 213

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE92Target Mapping Buttons N/AMapping and Masking FC and FCoE Po

Strany 214 - Application Situations

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE93Figure 8-14 LUN Masking TabLUN Masking Conventions and Guide

Strany 215 - ./stop_ocmanager

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE94To change the mask status of a LUN:1. Select Host view. 2. Fr

Strany 216

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE95Changing Automapping SettingsTo change automapping settings:1

Strany 217

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE962. In the discovery-tree, select the adapter port you want to

Strany 218

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE974. Click Bind New Target. The Bind New Target dialog box is d

Strany 219 - Situations

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE98 To avoid address conflicts, do not assign a WWNN or WWPN wi

Strany 220

OneCommand™ Manager Application P007997-01A Rev. B8. Managing Adapters and PortsFC/FCoE993. Select the Maintenance tab.Figure 8-18 Maintenance Tab4.