OneCommand™ Manager Application P007997-01A Rev. B
14. Troubleshooting
VPorts and OneCommand Manager Application Situations
220
Port not ready. The controls in the New Virtual Port box of the Virtual Port
window are replaced by a list of reasons why VPorts cannot be
created. The reasons can be one or more of the following:
•The driver NPIV parameter is disabled.
SLI-3 is not being used by a port.
Adapter port is out of resources for additional virtual ports.
The port is not connected to a fabric.
The fabric switch does not support virtual ports.
The fabric switch is out of resources for additional virtual
ports.
The port link state is down.
Table 14-4 VPorts and OneCommand Manager Application Situations
Situation Resolution