OneCommand™ Manager Application P007997-01A Rev. B
13. Diagnostics
LightPulse FC HBA Diagnostics
196
Viewing Overlay Details
If you double-click on a flash overlay, another window appears with details about that
overlay.
Figure 13-2 Overlay Detail Window
To see the details of a different flash overlay image, you can either close the details
window and double-click on another overlay name, or choose a different overlay name
from the Flash overlay menu.
Viewing the PCI Registers
The PCI Registers appear directly on the Diagnostics tab.
Running a Quick Test
The Diagnostics tab enables you to run a “quick” diagnostics test on a selected adapter.
The Quick Test consists of 50 PCI Loopback test cycles and 50 Internal Loopback test
cycles. (Not available in read-only mode or on LightPulse adapters in ESXi hosts.)
Note: Internal and External Loopback tests are not available for LP2100 and LP21002
adapters.
To use quick test:
1. From the discovery-tree, select the adapter port on which you want to run the
Quick Test.